Now the parameter will appear under Fire Protection and will be blank. In the Formula column, just write “=FireReq_FireRatingWall”.
This will have identical values on both parameters.
Note: In this case the FireReq_FireRatingWall parameter is used, but in other cases it might be needed to manually enter values or use other BFT provided parameters.