Sometime in projects it is necessary to add Shared Parameter from a family into the project,
whether it can be a Sheet parameter or just a parameter from a family.
The methodology that BFT is using to send parameters to the other stakeholders is to have each parameter in the project
as Shared Parameters, but only on the category it is affecting (Doors, Windows, Floors, Walls etc.) and HVAC zones.
They are assigned to HVAC zones only because it makes it possible to have all parameters in one schedule, it is of course possible to use any other category that might not be used in great extents in projects.
Start by editing the family which to take the shared parameter from.
Select the family and under Modify tab, click on Edit Family
In this example the keylock will be used.
Next is to check that Revit is connected to the correct Shared Parameter text file.
Sometimes it can just be easier to create a new Shared Parameter file in the project location.
Go to Manage → Shared Parameters
In this example let us create a new Shared Parameter and place it in the Project folder.
Naming convention can vary from company to company, but recommended to have a unique name, i.e.
Project Name_Shared Parameters
Finish with ok
Open the Family Type in Family editor in the Create tab
Select the parameter to transfer from the family to the project.
Going to show with FireReq_TypeOfLock in this example.
Select the pen in the bottom left
Export the parameter to the new Shared Parameter file.
If the Export button is greyed out. Check that the Shared Parameter is connected under
“Manage → Shared Parameter”
Or the parameter already exist in some group in the Shared parameter file.
Press ok, it will automatically create a group in the Shared Parameters file named “Exported Parameters”.
Cancel/Ok all and go back to the project.
Go to Manage → Project Parameters
Add
Select Shared parameter, the newly created “Exported Parameters” group with the parameter will appear.
In the Parameter Properties, add everything like shown in the picture.
The only thing that might vary is the Categories it should be attached to.
Always attach to HVAC zones + the category in the recipient’s model, in this case Doors.
It is now possible to add the parameter in the HVAC schedule to be sent to the other stakeholders.
Use the arrows between the columns to add and remove parameters.
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.