Use own symbols
There are very few requirements from using own symbols with BFT, below lists the requirements and “nice-to-have”.
Revit 2020 – Revit 2021
-
- Categories: Must be either Generic Model or Fire Alarm Device
- Generic Models are used for Wall compartmentation, the name must contain Fire_FireCompartmentation for Connect Fire Rating and Legend tool to work. If the family has a parameter Fire_Top, quick wall compartmentation will enter that value on that length parameter.
- If the family has a text parameter named Fire_GUID, the tool will automatically write the linked objects GUID on that tool. It will automatically write “-“ when not being able to to connect. Not necessary.
- All parameter values that want to be sent to other stakeholders, must be instance parameters.
Revit 2022 –
-
- New categories have been introduced: Audio Visual Devices, Electrical Equipment, Fire Protection, Mechanical Equipment, Security Devices and Speciality Equipment in addition to Fire Alarm Device and Generic Model.
- Fire Protection are used for Wall Compartmentation and Opening Requirement. The name for wall compartmentation must contain Fire_FireCompartmentation for Connect Fire Rating and Legend tool to work. If the family has a parameter Fire_Top, quick wall compartmentation will enter that value on that length parameter.
Note: Generic models works as well, if a project is updated.